• RoHS2.0 Material Detection and Organic Compound Testing Machine (GW-2600)
  • RoHS2.0 Material Detection and Organic Compound Testing Machine (GW-2600)

RoHS2.0 Material Detection and Organic Compound Testing Machine (GW-2600)

Max Diameter of Workpiece: Max.Preassure 6000psi
Mass Scope of Workpiece: <900kg
Type: Safety Footwear Testing Machine
Maxcapacity: Wavelength Range: 190-700 Nm
Accuracy Grade: 0.001-10.000ml/Min  0.01-80ml/Min
Load Way: Electronic Load
Gold Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GW-2600
Loading Method
Dynamic Load
Display
Computer Display
Control
Computer Control
Weight
0-100Kg
Power Source
85-264V/47-63Hz/60W
Oil Cylinder Position
Electric Control
Packaging
Wooden Case
Export Markets
Global
Model No
Gw-2600
Traffic Accuracy
<+/-1% 2UL/Min
Flow Range
0.001-10.000ml/Min 0.01-80ml/Min
Accuracy
0.25% (0.1ml/Min-10ml/Min)
Maximum Pressure
6000pasi (with High Voltage Protection)
Volume
115*46*80cm
Size
26 Cm X 36 Cm X 17 Cm
Power
85-264V, 47-63Hz, 60W
Transport Package
Standard Export Safety Packing
Specification
6.3KG
Trademark
Great Win
Origin
China
HS Code
9024800000
Production Capacity
500 Pieces/Year

Product Description

RoHS2.0 Material Detection And Organic Compound Testing Machine (GW-2600)

RoHS2.0 Material Detection and Organic Compound Testing Machine (GW-2600)



The GW-2600 is one of the most well-developed LC series products. The product uses precision high pressure infusion pump (1) with variable wavelength UV detector, to achieve the majority of organic compounds separation and detection. Including polybrominated biphenyls, polybrominated diphenyl ethers in the RoHS directive, phthalates in the REACH Directive, formaldehyde and polycyclic aromatic hydrocarbons in the EN71 Toy Directive; and organic chlorine tests: 4-chlorotoluene, 5-chloro Toluene, bisphenol A, azo fuel, aromatic amine and other tests.

 

Instrument features:
GW2600 pump features
It uses the CPU to control the reciprocating double plunger rod series pump head and patented design of the "floating pump plunger rod ring" technology, to achieve the user is essential to the two functions: 1.automatic emptying; 2.automatic cleaning The Effectively extending the service life of plunger rods and seals. With the analysis, semi-preparation and preparation of a variety of pump head type for users to choose. Pump head external, easy to replace and repair parts. With a complete pre-cleaning function, easy to replace the solvent quickly. Excellent self-priming check valve design and advanced "floating pump plunger ring" technology combination, so that LC-200A infusion pump in the 0ml / min-10ml / min flow range can withstand pressure 6000Psi ( 1Mpa = 145Psi), and the pressure fluctuation is much less than 10Psi, becoming one of the smallest pressure fluctuations at home and abroad. LC-200 series ASI501 high pressure constant current pump with flow system error compensation and high and low voltage protection, alarm function. RS-485 external communication interface design, can be realized by the workstation external control, and the workstation can be timely display the pump running a variety of parameters.
 
1, flow stability, minimal pressure fluctuations
2, the gradient is mixed completely, the baseline is stable
3, automatic emptying, automatic cleaning function
 
GW2600 Detector Features

It uses a digital output function, the signal output can be directly connected to the computer through the RS-232 or USB conversion interface without any data acquisition unit, to avoid the signal multiple conversion, making the performance more stable, reducing the detector baseline noise And drift, improved detection sensitivity. The optical path system adopts the precision positioning structure and unique heat dissipation technology, which has the characteristics of high precision, small offset and fast settling time. Unique pool structure, efficient optical system and digital filtering greatly improve the instrument's sensitivity, accuracy and repeatability, and the instrument has a superior noise level. Detector with imported German deuterium lamp and deuterium lamp power supply, long life, extremely stable and safe and reliable. Replace the deuterium lamp, do not have to adjust the optical axis, easy maintenance. High brightness LED display, with excellent visual effects and high quality stability. The instrument has a security alarm and automatic troubleshooting function, easy maintenance.
 
1, superior baseline noise and drift levels
2, detection of high sensitivity and high reproducibility, accuracy
3, high stability and reliable, easy to operate
 
Instrument Specifications
GW2600 pump technical parameters
Flow Accuracy  <±1%  2μl/min
Flow range  0.001-10.000ml/min  0.01-80ml/min(preparation)
Accuracy 0.25% (0.1ml/min-10ml/min)
Max pressure  6000pasi(Equipped with high and low voltage protection)
Size  26cm×36cm×17cm
Weight  6.3kg
Power 85-264v,47-63HZ,60w
   

Gradient program
You can edit and store 60 methods that can run complex gradient programs. Each method can be edited, 20 traffic adjustment steps, and can achieve horizontal and function gradient.
Remote control mode
  Can be controlled by external contact closure.
Traffic accuracy <±1%  2μl/min

GW2600 detector technical parameters
D2 lamp  life of 3500 hours, to ensure the use of 1000 hours, 1000 hours out of the trouble free replacement.
Wavelength range  190-700nm
Bandwidth  ≤6nm
Wavelength accuracy  ± 1nm
Wavelength repeatability  ± 0.1 nm
Absorption range  0.0005AU / mV-4AU / mV
Data system output  4AU / V
Noise  ≤ ± 2x10-5AU
Drift  ≤ 4x10-4AU (P-P)
Size  6.25 "W x 10" D x 16 "H
Weight  13.7 lbs. (6.0kg)
Power  100 to 240 VAC, 50 to 60Hz, 80watts

 
Instrument software configuration
1, with a detailed record of the experimental information function to ensure that the experimental test data of the original;
2, set the sampling time and voltage range;
3, points method: including the law, the external standard method, the standard method, the index method;
4, analysis report: can edit the header and footer, the spectrum shows the background, the contents of the peak notes, etc., and in accordance with the need to choose
The items shown in the report. You can save and print PDF reports.
5, the data automatically save: all samples of the test data will be automatically saved, the test results are traceable;
6, the baseline deduction function: according to the need to select the baseline file for baseline deduction;
7, the software is divided into two online and offline, online for sample detection data collection, offline for spectrum processing.
 
 
 

Instrument software features
1, theoretically no limit to increase the working curve in order to test a number of substances at once;
2, user-friendly software interface and operating methods, the use of unique graphics display technology, both convenient and intuitive; combined with a large number of operational experience to optimize the operating steps, great convenience to users;
3, the peak processing methods: manual integration or automatic integration, to avoid the resulting error.
4, data management: test data automatically generated, can not be changed. Query printing, test method management is very convenient.
Chun Hui Teng Technology is the leading domestic, providing REACH detector, high performance liquid chromatography, domestic RoHS detector, RoHS2.0 detector, Diana ion chromatograph, PAHs (polycyclic aromatic hydrocarbons) detector, PBB (polybrominated biphenyl) detection Instrument, PBDE (PBDE) detector, 6P (phthalate detector), 16P tester, GC-MS, AAS, XRF, halogen tester, a comprehensive solution of the service manufacturers.
RoHS2.0 Material Detection and Organic Compound Testing Machine (GW-2600)RoHS2.0 Material Detection and Organic Compound Testing Machine (GW-2600)RoHS2.0 Material Detection and Organic Compound Testing Machine (GW-2600)RoHS2.0 Material Detection and Organic Compound Testing Machine (GW-2600)RoHS2.0 Material Detection and Organic Compound Testing Machine (GW-2600)RoHS2.0 Material Detection and Organic Compound Testing Machine (GW-2600)RoHS2.0 Material Detection and Organic Compound Testing Machine (GW-2600)RoHS2.0 Material Detection and Organic Compound Testing Machine (GW-2600)
What about the product quality? 
For our products, each instrument must be carried out 100% quality calibration and test when delivery goods. With CE certificate, we are very confident in our products, and we will pack them with safety wooden case to protect the machine when transport oversea. 

What about usage of the machine? 
We will also give your professional guidance(Product operating manual and video), each products comes with a USB flash drive which have all the details. 

What about warranty? 
Guarantee one years( if the parts damage within one year, we can replace the part for free)
If customer need any technical support, we can help them solve their problem through email, video meeting. We also can provide door to door service, but customer need to bear the travel fees. 

What about standards support? 
We are strictly following different international standards such as EN, ISO, ASTM, AATC, JIS, GB ect, and had been recognized by SATRA, CSA international standard agency. 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now