Equipment Description:
Thermal Deformation Temperature Test Machine mainly used for the thermal deformation of the polymer materials
(plastics, rubber, nylon, electric insulating materials, etc. ) and Vicat softening point temperature determination.
Apply to universities, research institutes and Product Quality Supervision and Inspection unit. Heated media
Inside the 45 ° Double helix automatic mixing system, the tank has a special structure, temperature uniformity,
And maintain the accuracy of ± 0.5 ° C. And the use of advanced thyristor-controlled temperature,
Displacement sensor has a fine-tuning, fine tuning the dual adjustment method, with emergency stop switch,
The structure of the locked door after the Control Panel, machine maintenance, easy maintenance, the lift
System as one of themodels to reduce the noise. Therefore, the medium temperature gradient is uniform,
Constant temperature limit is reached when the test temperature to stop heating automatically when the set
Temperature, the test frame with automatic lift function, simple operation, with excellent cost performance in
Similar models.
Meet the Standards:
GB / T 1633-2000 (idt ISO 306: 1994) Vicat softening temperature (VST) determination
GB / T 1634.1-2004 (idt ISO75-2: 2003) plastic load deformation temperature measurement (Common test
Methods)
GB / T 1634.2-2004 plastic load deformation temperature measurement (plastic, hard rubber, and long fiber
Reinforced composites)
GB / T 1634.3-2004 plastic load deformation temperature determination (high-strength thermosetting
Laminates)
GB / T 8802-2001 (eqv ISO 2507: 1995) thermoplastic pipes, fittings Determination of Vicat softening
Temperature
Technical Specifications:
Temperature range |
room temperature -300 °C |
Heating rate |
120 ° C / h, 50 ° C / h |
The maximum temperature measurement error |
+0.5 ° C |
The maximum temperature control error |
+12 °C / min (heat distortion test)+5°C (Vicat test) /6 minutes |
Heat deflection |
Table 1, Table 2 |
The Vicat change deflection |
1mm |
The maximum deformation measurement error |
+0.005 mm |
The number of sample holder |
3 |
A weight to weight (ie, load lever, standard head,
the sensor probe, trays, screws) |
68g +1 g |
Heating medium |
methyl silicone oil (200 cSt below the flash point of 300°C and above) |
Maximum heating power |
3kw |
Cooling |
Natural cooling or water cooling |
Main Power |
220V +10%, 15A, 50HZ |
Weight
Specification |
A |
B |
C |
D |
E |
F |
G |
H |
I |
J |
K |
Quality(g) |
1000 |
932 |
500 |
200 |
100 |
50 |
20 |
10 |
5 |
2 |
1 |
number |
12 |
3 |
3 |
6 |
3 |
3 |
6 |
3 |
3 |
6 |
3 |







What about the product quality?
For our products, each instrument must be carried out 100% quality calibration and test when delivery goods. With CE certificate, we are very confident in our products, and we will pack them with safety wooden case to protect the machine when transport oversea.
What about usage of the machine?
We will also give your professional guidance(Product operating manual and video), each products comes with a USB flash drive which have all the details.
What about warranty?
Guarantee one years( if the parts damage within one year, we can replace the part for free)
If customer need any technical support, we can help them solve their problem through email, video meeting. We also can provide door to door service, but customer need to bear the travel fees.
What about standards support?
We are strictly following different international standards such as EN, ISO, ASTM, AATC, JIS, GB ect, and had been recognized by SATRA, CSA international standard agency.